Item type:Doctoral Thesis, Open Access

Dosimetric assessment of [68Ga]Ga-PSMA-11 PET/CT towards increasing the clinical impact in the management of patients with advanced prostate cancer

Loading...
Thumbnail Image

Publisher

Supervisors

Item type:Person,
Item type:Person,

Abstract

Introduction: Prostate‑specific membrane antigen (PSMA) has emerged as a highly specific molecular target for both diagnostic imaging and radioligand therapy in metastatic castration‑resistant prostate cancer (mCRPC). Reliable quantification of radiotracer kinetics is essential for personalized dosimetry, particularly for [177Lu]Lu‑PSMA‑617 radioligand therapy. However, conventional multi‑time‑point imaging protocols are resource‑intensive and difficult to implement in routine clinical practice. This thesis therefore, pursued a combined preclinical and clinical strategy in which the preclinical findings were used to design, optimize, and justify a simplified clinical dosimetry workflow based on segmentation, reconstruction, and pharmacokinetic modelling. Methods: The preclinical part employed dynamic PET and static SPECT/CT imaging in murine and chorioallantoic membrane (CAM) models to systematically evaluate segmentation strategies, reconstruction parameters, and kinetic modelling frameworks. Gradient‑based and threshold‑based volumes of interest (VOIs) methods were compared, and reconstruction stability was assessed across ordered‑subsets expectation‑maximization (OSEM) parameter variations. Dynamic murine PET data enabled the derivation of arterial input functions, parent‑fraction curves, and multi‑tissue time–activity curves, supporting one‑ and two‑tissue compartment modelling. The insights gained from these preclinical experiments, particularly regarding segmentation robustness, reconstruction stability, and the suitability of the two‑tissue compartment model, were directly translated into the clinical workflow. The clinical part included 35 mCRPC patients undergoing [177Lu]Lu‑PSMA‑617 radioligand therapy. Planar and/or SPECT/CT imaging was performed at 24 h and 48 h post‑injection. A total of 259 organ‑specific time–activity curves (across kidneys, salivary glands, liver) were generated using population‑based pharmacokinetic (PBPK) modelling. Validation was performed in 20 patients with multi‑time‑point reference dosimetry (2–196 h). Baseline [68Ga]Ga‑PSMA‑11 PET/CT was used to derive voxel‑based pre‑therapy dose coefficients. Accuracy was assessed using relative deviations, root mean square error (RMSE), mean absolute error (MAE), Bland–Altman analysis, and linear regression. Results: Preclinical investigations demonstrated that gradient‑based segmentation provided superior boundary conformity and reproducibility, particularly in the CAM model. Reconstruction analysis identified a parameter window in which standardized uptake value stability and VOI reproducibility were maintained. Kinetic modelling showed that the two‑tissue compartment model yielded physiologically meaningful fits, supported by high‑quality arterial input functions and parent‑fraction corrections. These preclinical findings formed the methodological foundation for the clinical PBPK workflow, ensuring that segmentation, reconstruction, and modelling choices were evidence‑based and optimized prior to clinical application. Clinically, the two‑time‑point PBPK approach produced time integrated activities (TIAs) and absorbed doses closely matching multi‑time‑point reference dosimetry. Median relative deviations were about 12%, and RMSEs ranged from 6.2% to 12.4% across organs. Pre‑therapy [68Ga]Ga‑PSMA‑11 PET/CT dose coefficients correlated strongly with first‑cycle absorbed doses (R2 = 0.74–0.89). Bland–Altman analyses showed minimal bias (<0.1 Gy/GBq) and clinically acceptable limits of agreement, with over 90% of estimates within ± 20% of reference values. Conclusion: This thesis demonstrates that a simplified two‑time‑point PBPK dosimetry workflow, informed and optimized by preclinical segmentation, reconstruction, and kinetic modelling studies, provides reliable and reproducible time integrated activities and absorbed doses for [177Lu]Lu‑PSMA‑617 radioligand therapy. The workflow achieves accuracy comparable to multi‑time‑point protocols while substantially reducing imaging burden. Pre‑therapy [68Ga]Ga‑PSMA‑11 PET/CT further enables reliable prediction of first‑cycle organ doses. Together, these findings establish a validated, scalable workflow that supports routine personalized dosimetry in PSMA‑targeted radioligand therapy.

Review

Metadata

show more
Bagheri, Shamim: Dosimetric assessment of [68Ga]Ga-PSMA-11 PET/CT towards increasing the clinical impact in the management of patients with advanced prostate cancer. : 2026-09-14.

License

This item has been published with the following license: In Copyright

Related Items

isSupervisorOfThesis

Item type:Person,
Item type:Person,