The doctor thesis presents an analyses of the measurement results of the passive solar office building Cölbe. The aim is to give an assessment of the subsystems active-solar heating system and ventilation system as far as the building demand itself is concerned. Basing on the measurement experiences theoretical parameter analyses for a theoretical reference building are done. Comparing different methods, relevant parameters for the building itself and its heating and distribution systems are extracted as far as the efficiency of the whole system is concerned (represented by the so-called Anlagenaufwandszahl). In this context the different methods (differential sensitivity analyses, reduced factorial design and Monte Carlo analyses) are discussed and assessed as well. Furthermore, on the basis of the results of the sensitivity analyses a comparison between the solar assisted reference building and a conventional building is presented as far the cumulated energy demand is concerned.